Anesthesia Workstation
50000.00 INR/Unit
Product Details:
- Weight 136-170 Kilograms (kg)
- Application For Hospital
- Dimension (L*W*H) 53.4 x 29.5 x 32.7 (HXWXD) Inch (in)
- Use Operation Use
- Product Type Anaesthesia Machine
- Color Code White
- Click to View more
X
Anesthesia Workstation Price And Quantity
- 50000.00 INR/Unit
- 1 Unit
Anesthesia Workstation Product Specifications
- White
- Anaesthesia Machine
- For Hospital
- 53.4 x 29.5 x 32.7 (HXWXD) Inch (in)
- Operation Use
- 136-170 Kilograms (kg)
Anesthesia Workstation Trade Information
- 10 Unit Per Day
- 15 Days
- No
- East India
Product Description
Anesthesia Workstation
Feature:
- Compact Anesthesia Ventilation System With The Standard Of Iso 9001:2015
- Easy To Operate, User Friendly
- Ventilation Parameters Monitoring, Preset Parameters, Alarm Indication And Breathing Waveform Monitoring
- Support Adult And Pediatric
- Applied For Closed, Semi-closed, Semi Open Inhalation Anesthesia Controlled Or Assisted Ventilation
Technique Specifications:
- Dimensions: 70*85*140cm.
- Weight: 50kg.
- Casters: Front Wheels With Lock.
- Screen: Lcd.
- Display: 7 inch.
- Display Graphics: Waveforms Of P-t,f-t.
- Monitoring: Vt, Mv, Bpm, Paw, Lung Compliance, Inspiratory Platform, Fio2
Working Specifications:
- Power: Ac 220v+10%, 50hz+2%. -output Pressure: 0.4+0.1mpa.-current: 500ma Max
Ventilator Specifications:
- Modes Of Ventilation
- Vcv: Volume Controlled Ventilation.
- Simv: Synchronized Intermittent Mandatory Ventilation.
- Manual: Manual. Sippv (A/c): Synchronized Intermittent Positive Pressure Ventilation.
- Pcv: Pressure Control Ventilation.
- Stand-by: Stand-by
System Standard:
- Hypoxic Guard System: N2o Cut
- Off Valve, 02 Concentration>25%.
- Safety Valve: <12.5kpa.
- Fresh Gas Compensation: 25-75l/min.
- Flowmeter: Cascade, 0-10l/min.
- Volume Of Co2 Absorber: 1.5l.
- Vaporizer: 1 Selectetac, Maximum 2 Mounts (Isoflurane/enflurane/sevoflurane/halothane.
Ventilator Parameter:
- Working Type: Electronically Controlled, Pneumatic Driven.
- Tidal Volume Range: 20-1500ml.
- Pressure Range: 5-80 Mbar.
- Respriation Rate Range: 1-99bpm (1-40bpm Under Simv).
- I: E Range: 4: 1-1:8.-p trigger Range:-20-20cmh2o.
- Minute Volume Range: >18l/min.-sigh Range: 0-5/100,
- Type: Integrated, Electronic Control
- Alarm Limits
- Audio/visual: No Tidal Volume, Mv, Paw, Fi02 Limitation 02, Air Failure, Ac Power Failure, Battery Low.
- Pipeline Suppiy
- Gas Configuration: 02, N2o.-pipeline Input Range: 280-600kpa
- Battery Power
- Battery Type: Lead-acid 12v, 4ah.-run-time: Typical 30mins+,up To 2 Hrs
- Pre-setting Functions
- Language: English.
- Calibration: Automatic
Applications:
- Patient Range: Adult/pediatric
- Peep
Type:
- Integrated,
- Electronic Control.-range:off, 3-20 cm H2o
Optional:
- Acgo: Auxiliary Common Gas Outlet.
- Vaporizer: Selectatec.
- Yoke System (Pin-index): Support 11l Cylinder, 02/n2o.-agss: Anaesthetic Gas Scavenging Systems